YILDIZ TECHNICAL UNIVERSITY FACULTY OF ARCHITECTURE E-JOURNAL

E-ISSN 1309-6915
Volume: 19 Issue: 1
Year: 2024

Current Issue Published Issues Most Accessed Articles Ahead of Print
Index and Coverage
Avery Index
DOAJ
EBSCO
Erih Plus
ESCI – Clarivate
GALE Cengage
Genamics
ProQuest
TR Dizin
TUBITAK Ulakbim
Ulrichs Web
IdealOnline
The effect of building height and street width on indoor daylight performance according to the town planning code – office buildings for the case of Istanbul and Adana [Megaron]
Megaron. 2023; 18(4): 466-482 | DOI: 10.14744/megaron.2023.79577  

The effect of building height and street width on indoor daylight performance according to the town planning code – office buildings for the case of Istanbul and Adana

Pınar Aydın, Rengin Ünver
Department of Architecture, Yıldız Technical University, İstanbul, Türkiye

Due to the concept of sustainability, it has become increasingly important to reduce the energy burden of lighting by promoting the use of natural light. In daylighting design, there are several variables that affect the performance of daylight indoors. “External obstructions,” which is one of the variables that significantly affect daylight penetration into the volume, are often limited by legislation such as the zoning plan/ordinance, etc. of the city/settlement. In this article, non-structural obstructions at different heights and distances were first determined for attached office buildings within the scope of the “Planned Areas Type Zoning Regulation” in force in Türkiye. The daylight performance of these spaces in the attached structures of office spaces of 2-storey (B2), 5-storey (B5), and multistorey buildings in Istanbul and Adana were investigated according to TS EN 17037, considering the four window directions (K – North, D – East, G – South, and B – West), three light transmission factors (0.8, 0.6, and 0.4), and a transparency ratio of 0.3. Among the optimal options identified for the office buildings considered in the study, the most positive situations were identified among those with appropriate daylight and luminance according to the function, according to the criteria of TS EN 17037. For the scenarios without negative daylight criteria, suggestions were made to improve integrated lighting systems where natural and artificial lighting coexist. Thus, the performance of the daylight entering the volume would be determined at the design stage and the energy to be spent on artificial lighting could be reduced.

Keywords: Daylight, office, planned areas type zoning, regulation, TS EN 17037, visual comfort.


Pınar Aydın, Rengin Ünver. The effect of building height and street width on indoor daylight performance according to the town planning code – office buildings for the case of Istanbul and Adana. Megaron. 2023; 18(4): 466-482

Corresponding Author: Pınar Aydın, Türkiye


TOOLS
Full Text PDF
Print
Download citation
RIS
EndNote
BibTex
Medlars
Procite
Reference Manager
Share with email
Share
Send email to author

Similar articles
PubMed
Google Scholar




© 2024 Yıldız Teknik Üniversitesİ Mimarlık Fakültesİ



LookUs & Online Makale